ResMed H4i™ Humidifier Water Chamber Replacement - Dishwasher Safe
The ResMed Dishwasher Safe Replacement Water Chamber for the H4i™ Humidifier is an easy-to-clean replacement water chamber that can simply be washed on the top rack of your dishwasher once weekly. This replacement water chamber is compatible with the ResMed H4i™ humidifier and ResMed S8 and S8 AutoSet™ II CPAP machines and features a comfortable, ergonomic design.
Please note that this product is the water chamber only and does not include the heated humidifier or any other parts or accessories. Other options for the H4i™ humidifier regarding the water chamber include the non-dishwasher safe version of the H4i™ tank as well which needs to be manually cleaned.
**This is a non-stock item from the manufacturer, please allow 2 - 4 weeks for delivery.
The ResMed H4i™ Humidifier Water Chamber Replacement is an easy-to-clean water chamber that can simply be washed on the top rack of your dishwasher.
This replacement water chamber is compatible with the ResMed H4i™ humidifier and ResMed S8 and S8 AutoSet™ II CPAP machines and features a comfortable, ergonomic design. The chamber is made from durable, BPA-free material and has a capacity of 380mL, making it perfect for those who need longer humidification during the night. The dishwasher-safe design of this chamber means that you can easily clean it once a week, without having to worry about taking apart your CPAP machine.
Tips for use of the ResMed H4i™ Water Chamber
- Never overfill the water tank above the maximum fill line as damage may possibly occur to either the humidifier or the S8 CPAP therapy device.
- Please be sure to use only distilled water in the water tank that is preferably at room temperature. Do not under any circumstances use any additives or additional chemicals with the distilled water.
- When removing the hose/tubing from the H4i™ water chamber outlet, please be careful that there is no leftover water inside the tubing as this could reach the CPAP device and cause possible damage.
- Should you need to move or transport the H4i™ Humidifier, you must remove the water chamber, empty any leftover water and then reconnect with the humidifier base.
- When filling the water chamber, please make sure to separate it from the H4i™ humidifier first before doing so. This can result in damage to the humidifier base or the S8 CPAP device.
- If there is still leftover distilled water in the tank, please make sure to remove the water tank from the humidifier before disconnecting the therapy device in order to avoid possible spillage.
- When removing the water chamber from the humidifier, please make sure that the humidifier door is set to the open position.
- Please do not turn the humidifier on if there is no distilled water in the H4i™ water chamber. Should you wish to not use the humidifier during your CPAP therapy session, please make sure that the number setting is on 0 on your device.
**This is a non-stock item from the manufacturer, please allow 2 - 4 weeks for delivery.
Features:
- Made from durable, BPA free non-toxic materials
- 390 ml capacity for longer humidification sessions
Benefits:
- Easy to clean and maintain (Dishwasher safe)
- Compatible with H4i™ Humidifier that works with ResMed S8 and S8 II CPAP machines.
Ideal For:
- People who suffer from a blocked, stuffy feeling and nasal congestion during CPAP therapy
- People who own H4i™ base units that are compatible ResMed S8 and S8 II devices
- 1 x ResMed Dishwasher Safe Replacement Water Chamber for Humidifier H4i™
Manufacturer | ResMed |
SKU | 26958 |
Product Dimensions | (Chamber and docking station) 130 mm x 170 mm x 212 mm (5.0” x 6.7” x 8.3”) |
Product Weight | Docking Station and Unfilled Water Chamber: 774 g (1.7 lbs.). |
Water Capacity | 390 ml. |
Other Chamber Options | View (Not dishwasher safe) |
Compatible With | ResMed S8 |
How Frequently to Change | ResMed recommends replacement every 6 months or as needed |
How To Clean | ResMed recommends weekly cleaning in warm water using a mild dishwashing liquid OR in a solution with a ratio of 1 part vinegar and 9 parts water at room temperature. This model water chamber is also dishwasher safe on the top rack. |
Product Manual | ResMed Dishwasher Safe Replacement Water Chamber for H4i™ Guide |
Helpful Videos |
How humidification helps with CPAP treatment How to disassemble the ResMed H4i™ Humidifier Water Chamber for cleaning |
Q: With what units is the ResMed Dishwasher Safe Replacement Water Chamber for H4i™ safe to use with?
A: It is only compatible and to be used with the H4i™ Base Unit Humidifiers that are compatible ResMed S8 CPAP devices.
Q: Can I put the ResMed Dishwasher Safe Replacement Water Chamber for H4i™ in the dishwasher?
A: Yes. ResMed recommends placing and only cleaning this water chamber on the top rack of the dishwasher to prevent any possible damage to the component.
Q: What is the benefit of using a humidifier during CPAP therapy?
A: A humidifier will help reduce the possibility of CPAP rainout and congestion while providing you with a comfortable and relaxed night of sleep. If you suffer from a dry throat, allergy type symptoms or general nasal congestion after CPAP therapy, then a humidifier would be the answer for you.
Q: Is ResMed Dishwasher Safe Replacement Water Chamber for H4i™ the only water chamber I can use?
A: No, you can also use the non-dishwasher safe unit. However, when cleaning this water chamber, you will need to wash this by hand as it is not dishwasher safe.
Q: How do you open the bottom of the Resmed H4i™ Water chamber for cleaning?
A: Turn the chamber around until you can see the ResMed logo.. To the left and right of the ResMed logo are two "wings", Pull those toward you and the bottom will pop open. This is how you open the bottom of the H4i™ Water chamber.